Major Components
The Sample-Vac System consists of the following major components:
Sampler Spool
The
316 SS spool piece can be made any size to be "tri-clamped"
into the existing process chute. It consists of an air
cylinder, which extends a machined shaft, with sample
cavity, into the process stream. The cavity fills with
powder and the shaft is then retracted from the process.
The sampling shaft resides in a Teflon bearing which
is purged and which is completely flush with the spool
piece wall, providing no protrusion into the process
when not being used. A filter is installed on the air
intake line.
Sample Jar and Primary Filter
The
sample is vacuumed to a jar and filter assembly which
can be mounted in a convenient location for access.
Sample jars can be provided in 8, 16 or 32 ounce sizes.
The primary filter element is pourous poyeltelene and
is replaceable. This assembly is connected to the sampler
via _" vacuum hose, which is easily removed and
replaced, rather than cleaned.
Vacuum Pump and HEPA Filter
The
PIAB vacuum pump is mounted on a HEPA filter assembly
which consists of a Black plastic housing and a quick
connect, _" push tube connection. The PIAB pump
is an MLLD100 pump. It requires a compressed air supply
of 12.5 psi @ 87 psi for optimum performance and is
capable of pulling a 28" Hg. Vacuum.
Pneumatic Control Panel
Controlling the entire sampling operation and sequencing is a completely pneumatic control panel. The panel includes adjustable timers for each step of the sampling operation. A pressure gauge, 3- way selector switch and "E-Stop" are conveneiently located on the front of the panel. Electronic panels for PLC interface are also available, if preferred or required.
If you have a sampling requirement, we hope that you will give us a call to discuss your specific requirements.
|